Features
- Please note that IBS-TH2 is compatible with the wifi gateway update version. The maximum range of 98ft(without obstacle) via Bluetooth connection, APP supports multi-language, °C /°F mode, and product with magnet base.
- Built-in temperature & humidity sensor, stores a maximum of 30,000 points of data on the device.
- Graph, accuracy calibrating, high/low-temperature alarm notification, data export, and the sampling interval set are supported via the app. Support for application scenario selection and addition.
- Digital LCD displays temperature and humidity, Bluetooth signal, and remaining battery power. An external waterproof temp&humditiy probe is included.
- The smart thermometer supports connection to multiple phones or reading multiple sensors with one cellphone. One phone can connect more than one IBS-TH2 PLUS at the same time. And one IBS-TH2 PLUS can be connected to more than one phone at the same time.
Built-in Temperature&Humidity Sensor
Temperature Measurement Range: -10℃~60℃/14℉~140℉
Temperature Accuracy
- Typical: ±0.3℃/+0.5℉
- Max: ±0.5℃/±0.9℉
Humidity Range: 0%RH-99%RH
Humidity Accuracy (25℃/77℉, 20%~80%RH)
- Typical: ±3%RH
- Max: ±4.5%RH
RH Humidity Accuracy(25℃/77℉, 0%~100%RH)
- Typical: ±4.5%RH
- Max: ±7.5%RH
External Temperature Probe
Temperature Measurement Range: -40℃~125℃/-40℉~257℉
Temperature Accuracy: ±0.5℃/±0.9℉
External Temperature&Humidity Probe
Temperature Measurement Range: 40℃~60℃/-40℉~140℉
Temperature Accuracy
- Typical: ±0.3℃/+0.5℉
- Max: ±0.5℃/±0.9℉
Humidity Range: 0%RH-99%RH
Humidity Accuracy (25℃/77℉, 20%~80%RH)
- Typical: ±3%RH
- Max: ±4.5%RH
RH Humidity Accuracy(25℃/77℉, 0%~100%RH)
- Typical: ±4.5%RH
- Max: ±7.5%RH

Bluetooth
If the data logger is connected to your phone via Bluetooth, then you can monitor and control the thermometers on Engbird app within a maximum distance of 98ft..
Display Screen
• The digital lcd displays temperature and humidity quickly and easily with a quick glance at the device.
• Remaining battery capacity is also displayed on the LCD screen.
Data Storage & Sampling Interval
Hold data for 20 days if the sampling interval is 1min, and the max date storage is 30000 points. Different sampling intervals can be set(10s/ 30s/ 1min/ 2mins/ 5mins/ 10mins/ 30mins) The number of days data is collected is dependent on the sampling interval.
Multi-function
The temperature probe sensor can be used in a refrigerator or a freezer. When the probe is plugged into the IBS-TH2, the IBS-TH2 will read and display the temperature of the probe.